ISSN 0303-5212
 

Original Research 
RMJ. 2020; 45(1): 107-110


Functional outcome with Kirschner Wire Fixation Versus Volar Locking Plate Fixation for management of patients with dorsally displaced fractures of distal radius

Naveed Ullah Khan, Abdul Qadir Khan, Muhammad Jameel, Hafiz Muhammad Yaqoob, Zeeshan Khan, Mubashar Ahmad Bajwa.

Abstract
Objective: To determine functional outcome by mean dash score with Kirschner wire fixation versus volar locking plate fixation for management of patients with dorsally displaced fractures of distal radius
Methodology: A total of 100 patients of dorsally displaced fractures of distal radius (50 in each group) were included in this study. Randomization was done by the lottery method. Group A fractures were fixed by percutaneous k-wires while in group B fractures were fixed by volar locking plate.
Results: Mean age of the patients was 46.70±8.86 and 45.72±9.11 years in group A and B, respectively. There were 34 males (68%) in group A and 33 males (66%) in group B while females were 16 (32%) in group A and 17 (34%) in group B. Right side was involved in 41 patients (82%) of group A and 37(74%) of group B. Left side was involved in 9 patients (18%) of group A and 13(26%) of group B. Mean dash score in group A was 31.49±3.17 and in group 20.96±3.17 (p<0.001).
Conclusion: Use of a volar locking plate resulted in better early post-operative function. Volar locking plate achieved better radiographic reduction and measured grip strength. An earlier recovery of function may be of advantage to patients.

Key words: Fixation devices. Kirschner wires, Radius Fractures.


 
ARTICLE TOOLS
Abstract
PDF Fulltext
How to cite this articleHow to cite this article
Citation Tools
Related Records
 Articles by Naveed Ullah Khan
Articles by Abdul Qadir Khan
Articles by Muhammad Jameel
Articles by Hafiz Muhammad Yaqoob
Articles by Zeeshan Khan
Articles by Mubashar Ahmad Bajwa
on Google
on Google Scholar

How to Cite this Article
Pubmed Style

Khan NU, Khan AQ, Jameel M, Yaqoob HM, Khan Z, Bajwa MA. Functional outcome with Kirschner Wire Fixation Versus Volar Locking Plate Fixation for management of patients with dorsally displaced fractures of distal radius. RMJ. 2020; 45(1): 107-110.


Web Style

Khan NU, Khan AQ, Jameel M, Yaqoob HM, Khan Z, Bajwa MA. Functional outcome with Kirschner Wire Fixation Versus Volar Locking Plate Fixation for management of patients with dorsally displaced fractures of distal radius. https://www.rmj.org.pk/?mno=76072 [Access: December 05, 2023].


AMA (American Medical Association) Style

Khan NU, Khan AQ, Jameel M, Yaqoob HM, Khan Z, Bajwa MA. Functional outcome with Kirschner Wire Fixation Versus Volar Locking Plate Fixation for management of patients with dorsally displaced fractures of distal radius. RMJ. 2020; 45(1): 107-110.



Vancouver/ICMJE Style

Khan NU, Khan AQ, Jameel M, Yaqoob HM, Khan Z, Bajwa MA. Functional outcome with Kirschner Wire Fixation Versus Volar Locking Plate Fixation for management of patients with dorsally displaced fractures of distal radius. RMJ. (2020), [cited December 05, 2023]; 45(1): 107-110.



Harvard Style

Khan, N. U., Khan, . A. Q., Jameel, . M., Yaqoob, . H. M., Khan, . Z. & Bajwa, . M. A. (2020) Functional outcome with Kirschner Wire Fixation Versus Volar Locking Plate Fixation for management of patients with dorsally displaced fractures of distal radius. RMJ, 45 (1), 107-110.



Turabian Style

Khan, Naveed Ullah, Abdul Qadir Khan, Muhammad Jameel, Hafiz Muhammad Yaqoob, Zeeshan Khan, and Mubashar Ahmad Bajwa. 2020. Functional outcome with Kirschner Wire Fixation Versus Volar Locking Plate Fixation for management of patients with dorsally displaced fractures of distal radius. Rawal Medical Journal, 45 (1), 107-110.



Chicago Style

Khan, Naveed Ullah, Abdul Qadir Khan, Muhammad Jameel, Hafiz Muhammad Yaqoob, Zeeshan Khan, and Mubashar Ahmad Bajwa. "Functional outcome with Kirschner Wire Fixation Versus Volar Locking Plate Fixation for management of patients with dorsally displaced fractures of distal radius." Rawal Medical Journal 45 (2020), 107-110.



MLA (The Modern Language Association) Style

Khan, Naveed Ullah, Abdul Qadir Khan, Muhammad Jameel, Hafiz Muhammad Yaqoob, Zeeshan Khan, and Mubashar Ahmad Bajwa. "Functional outcome with Kirschner Wire Fixation Versus Volar Locking Plate Fixation for management of patients with dorsally displaced fractures of distal radius." Rawal Medical Journal 45.1 (2020), 107-110. Print.



APA (American Psychological Association) Style

Khan, N. U., Khan, . A. Q., Jameel, . M., Yaqoob, . H. M., Khan, . Z. & Bajwa, . M. A. (2020) Functional outcome with Kirschner Wire Fixation Versus Volar Locking Plate Fixation for management of patients with dorsally displaced fractures of distal radius. Rawal Medical Journal, 45 (1), 107-110.