ISSN 0303-5212
 

Original Research 


Spot protein to creatinine ratio – a good alternative to 24 hour urinary protein for diagnosis of preeclampsia

Ayesha Basharat, Sarwat Navid, Mahwash Jamil, Samra Ayub, Asma Tanveer Usmani.

Abstract
Objective: To determine the validity of protein to creatinine ratio in comparison to 24-hour urine protein estimation in the diagnosis of preeclampsia.
Methodology: 150 pregnant women with preeclampsia defined as a BP > 140/90 and 1+ proteinuria at a gestational age > 20 weeks were recruited through outpatient department by performing a dipstick examination. A spot Protein creatinine ratio was done on mid-stream urine sample on the same day after admission. From the next voided specimen urine was collected for determination of 24 hrs urinary proteins.
Results: The mean age of the patients was 27.56±4.4 years and the mean gestational age was 34.9±2.87 weeks. 115 (76.67%) patients had positive 24-hour urine protein test for significant proteinuria. Out of these 115 (100%) also had a positive spot urine protein creatinine ratio test and none (0%) had a negative spot urine protein creatinine ratio test. Out of 150 patients, 35 (23.3%) had negative 24-hour urine protein test for significant proteinuria. Out of these, 1 (2.8%) had a positive spot urine protein creatinine ratio test and 34 (97.2%) had a negative spot urine protein creatinine ratio test (spot urine protein creatinine ratio test accuracy 99.3%). The calculated sensitivity and specificity of the Spot urine protein creatinine ratio test in comparison to 24-hour urine protein test was 100% and 97.14%, respectively. Positive predictive value (PV+) and negative predictive value (PV−) was found to be 99.1% and 100%, respectively.
Conclusion: Protein creatinine ratio in spot urine spe¬cimens is an accurate method and a good alternative to estimate the protein excretion in cases of preeclampsia.

Key words: Pre eclampsia, spot protein creatinine ratio, proteinuria.


 
ARTICLE TOOLS
Abstract
PDF Fulltext
How to cite this articleHow to cite this article
Citation Tools
Related Records
 Articles by Ayesha Basharat
Articles by Sarwat Navid
Articles by Mahwash Jamil
Articles by Samra Ayub
Articles by Asma Tanveer Usmani
on Google
on Google Scholar

How to Cite this Article
Pubmed Style

Ayesha Basharat, Sarwat Navid, Mahwash Jamil, Samra Ayub, Asma Tanveer Usmani. Spot protein to creatinine ratio – a good alternative to 24 hour urinary protein for diagnosis of preeclampsia. RMJ. 2017; 42(1): 64-67.


Web Style

Ayesha Basharat, Sarwat Navid, Mahwash Jamil, Samra Ayub, Asma Tanveer Usmani. Spot protein to creatinine ratio – a good alternative to 24 hour urinary protein for diagnosis of preeclampsia. https://www.rmj.org.pk/?mno=227134 [Access: December 05, 2023].


AMA (American Medical Association) Style

Ayesha Basharat, Sarwat Navid, Mahwash Jamil, Samra Ayub, Asma Tanveer Usmani. Spot protein to creatinine ratio – a good alternative to 24 hour urinary protein for diagnosis of preeclampsia. RMJ. 2017; 42(1): 64-67.



Vancouver/ICMJE Style

Ayesha Basharat, Sarwat Navid, Mahwash Jamil, Samra Ayub, Asma Tanveer Usmani. Spot protein to creatinine ratio – a good alternative to 24 hour urinary protein for diagnosis of preeclampsia. RMJ. (2017), [cited December 05, 2023]; 42(1): 64-67.



Harvard Style

Ayesha Basharat, Sarwat Navid, Mahwash Jamil, Samra Ayub, Asma Tanveer Usmani (2017) Spot protein to creatinine ratio – a good alternative to 24 hour urinary protein for diagnosis of preeclampsia. RMJ, 42 (1), 64-67.



Turabian Style

Ayesha Basharat, Sarwat Navid, Mahwash Jamil, Samra Ayub, Asma Tanveer Usmani. 2017. Spot protein to creatinine ratio – a good alternative to 24 hour urinary protein for diagnosis of preeclampsia. Rawal Medical Journal, 42 (1), 64-67.



Chicago Style

Ayesha Basharat, Sarwat Navid, Mahwash Jamil, Samra Ayub, Asma Tanveer Usmani. "Spot protein to creatinine ratio – a good alternative to 24 hour urinary protein for diagnosis of preeclampsia." Rawal Medical Journal 42 (2017), 64-67.



MLA (The Modern Language Association) Style

Ayesha Basharat, Sarwat Navid, Mahwash Jamil, Samra Ayub, Asma Tanveer Usmani. "Spot protein to creatinine ratio – a good alternative to 24 hour urinary protein for diagnosis of preeclampsia." Rawal Medical Journal 42.1 (2017), 64-67. Print.



APA (American Psychological Association) Style

Ayesha Basharat, Sarwat Navid, Mahwash Jamil, Samra Ayub, Asma Tanveer Usmani (2017) Spot protein to creatinine ratio – a good alternative to 24 hour urinary protein for diagnosis of preeclampsia. Rawal Medical Journal, 42 (1), 64-67.